4 Easy Steps To Reset Hjt Ip Camera To Factory Settings

4 Easy Steps To Reset Hjt Ip Camera To Factory Settings

In the event you’re having bother along with your HJT IP digital camera, resetting it to manufacturing unit settings generally is a fast and straightforward solution to get it working correctly once more. Here is the way to do it:

First, find the reset button in your digital camera. It is normally a small, recessed button positioned on the again or backside of the digital camera. As soon as you have discovered the reset button, press and maintain it for about 10 seconds. The digital camera will then reboot and the manufacturing unit settings will probably be restored.

After the digital camera has rebooted, you may have to reconfigure it. This consists of setting the digital camera’s IP tackle, subnet masks, and gateway tackle. You will additionally have to create a brand new person account and password. As soon as you have configured the digital camera, it’s best to be capable of use it usually.

Resetting Utilizing the Direct Methodology

This methodology requires bodily entry to the IP digital camera. Observe these steps:

  1. Find the Reset Button: Most IP cameras have a small reset button positioned on the underside or again of the machine. It could be recessed, so chances are you’ll want a paperclip or skinny object to press it.
  2. Press and Maintain the Reset Button: Press and maintain the reset button for about 10 seconds. The digital camera will usually beep or flash an LED to point that the reset course of has began.
  3. Launch the Reset Button: As soon as the reset course of has began, launch the reset button. The digital camera will reboot and return to its manufacturing unit default settings.

Be aware: The precise steps could fluctuate barely relying on the mannequin of IP digital camera. Check with the person handbook for detailed directions.

Digital camera Producer Reset Button Location
Axis Backside of the digital camera, behind the lens
Hikvision Again of the digital camera, close to the ability connector
Dahua Backside of the digital camera, hid by a rubber plug

Resetting By way of Net Interface

Entry the digital camera’s net interface by getting into its IP tackle into an internet browser. The default IP tackle for Hjt cameras is normally 192.168.1.10.

As soon as logged in, navigate to the “System” or “Configuration” tab.

Find the “Manufacturing unit Reset” or “Reset to Default” button. This can be positioned below the “Settings” or “Upkeep” part.

Verify the reset by clicking “OK” or “Verify.”

Await the digital camera to reboot, which can take a couple of minutes. As soon as the reset is full, the digital camera may have its default settings.

Extra Particulars for Resetting By way of Net Interface

Listed below are some further particulars to think about when resetting your Hjt IP digital camera via the online interface:

Reset button location: Usually discovered below the “System” or “Configuration” tab, and throughout the “Settings” or “Upkeep” part.
Affirmation required: Most cameras will immediate you to verify the reset earlier than continuing. Click on “OK” or “Verify” to proceed.
Reboot time: The digital camera will take a couple of minutes to reboot after the reset is initiated. Await the method to finish earlier than trying to entry the digital camera once more.

Be aware that resetting the digital camera to manufacturing unit settings will erase all customized settings, together with community configurations, person accounts, and movement detection parameters. It’s endorsed to make a backup of your present settings earlier than performing a reset.

Figuring out Default IP Deal with

Figuring out the default IP tackle of your HJT IP digital camera is essential for accessing its settings and resetting it to manufacturing unit defaults. Listed below are the steps to determine your digital camera’s IP tackle:

  1. Test the System Label: Many HJT cameras have a label on their backside or again that lists the default IP tackle.

  2. Use a Router’s DHCP Desk: Log into your router’s net interface and navigate to the DHCP desk. The desk will show all of the gadgets related to your community, together with your digital camera, and its assigned IP tackle.

  3. Scan for Units: Use a community scanning software, akin to Superior IP Scanner, to scan your native community for related gadgets. The software will offer you a listing of all detected gadgets, together with your digital camera’s IP tackle.

  4. Use a Default IP Record: Check with a listing of default IP addresses for HJT cameras. Widespread default IP addresses embody 192.168.1.100, 192.168.0.100, and 192.168.1.80.

  5. Contact Help: In the event you can not discover the IP tackle of your HJT digital camera utilizing the above strategies, contact the producer’s assist workforce for help.

Methodology The way to
Test System Label Examine the label on the digital camera’s physique for the default IP tackle.
Router’s DHCP Desk Log into your router’s net interface and discover the DHCP desk with related gadgets and their IP addresses.
Community Scanning Instrument Use a community scanner like Superior IP Scanner to detect your digital camera and its IP tackle.
Default IP Record Check with a listing of frequent default IP addresses for HJT cameras.
Contact Help Attain out to the HJT assist workforce for help if different strategies fail.

Resetting with ONVIF

The ONVIF (Open Community Video Interface Discussion board) protocol supplies standardized interfaces for IP cameras. It permits for the invention, configuration, and monitoring of IP cameras on a community. To reset an HJT IP digital camera to manufacturing unit settings utilizing ONVIF, comply with these steps:

1. Obtain and set up an ONVIF shopper

There are a number of ONVIF purchasers out there, akin to ONVIF System Supervisor and Milestone System Supervisor. Select one and set up it in your pc.

2. Uncover the IP digital camera on the community

Open the ONVIF shopper and uncover the IP digital camera on the community. The IP digital camera’s IP tackle will probably be displayed within the record of gadgets.

3. Connect with the IP digital camera

Choose the IP digital camera from the record and enter the username and password for the digital camera. This info may be discovered within the digital camera’s documentation.

4. Navigate to the System menu

As soon as related to the IP digital camera, navigate to the System menu within the ONVIF shopper. This menu could also be positioned below totally different sections relying on the shopper you might be utilizing.

5. Discover the Manufacturing unit Reset possibility

Within the System menu, find the Manufacturing unit Reset possibility. This feature could also be discovered below a subsection referred to as “Upkeep” or “Configuration.”

6. Verify the reset

Click on on the Manufacturing unit Reset button and ensure that you just need to reset the digital camera to manufacturing unit settings. The digital camera will now start the reset course of, which can take a number of minutes. As soon as the reset is full, the digital camera will reboot and be restored to its manufacturing unit default settings.

Parameter Default Worth
IP Deal with 192.168.1.108
Username admin
Password password

Troubleshooting Reset Points

If encountering points whereas resetting the HJT IP digital camera to manufacturing unit settings, discuss with the next troubleshooting suggestions:

8. Confirm Energy and Community Connectivity

Be sure that the digital camera is plugged in and powered on. Then, confirm that the Ethernet cable is securely related between the digital camera and your router or community swap. If the digital camera helps Wi-Fi, be certain it’s related to the proper Wi-Fi community and that you’ve entered the proper password.

If connectivity points persist, examine the next:

– Reset your router or community swap.
– Use a unique Ethernet cable to attach the digital camera.
– If utilizing Wi-Fi, transfer the digital camera nearer to the router or entry level.
– Test the digital camera’s community settings in its net interface to make sure they’re right.

Concern Resolution
Digital camera will not be powered on Guarantee the ability adapter is correctly related and the digital camera is switched on.
Ethernet cable will not be related Confirm the Ethernet cable is firmly plugged into the digital camera and your community machine.
Incorrect Wi-Fi password Double-check the Wi-Fi password and guarantee it’s entered accurately on the digital camera.
Digital camera is simply too removed from the router Transfer the digital camera nearer to the router or entry level to enhance sign power.
Incorrect community settings Test the digital camera’s community settings in its net interface and guarantee they match your community configuration.

Finest Practices for Resetting

1. Verify the Want for a Reset

Earlier than initiating a reset, confirm that the digital camera is not malfunctioning as a result of a software program replace or community connectivity points.

2. Disconnect from the Community

Unplug the Ethernet cable or disable Wi-Fi connectivity to stop information loss in the course of the reset course of.

3. Find the Reset Button

The reset button is often a small, recessed button positioned on the digital camera’s backside or again. Use a paperclip or toothpick to press it.

4. Press and Maintain the Button

Maintain the reset button for the desired period of time, normally round 10-15 seconds. Launch when the digital camera’s LED indicators flash or activate.

5. Await the Digital camera to Reboot

After releasing the reset button, the digital camera will routinely reboot and restore to manufacturing unit settings. This course of could take a couple of minutes.

6. Reconnect to the Community

As soon as the digital camera has rebooted, reconnect it to the community by way of Ethernet or Wi-Fi.

7. Reconfigure the Digital camera

Use the digital camera’s net interface or cellular app to reconfigure the settings, together with Wi-Fi community, password, and different customizations.

8. Check the Digital camera’s Performance

Confirm that the reset has resolved any points and that the digital camera is functioning correctly.

9. Retailer the Reset Info

Preserve a document of the default passwords, IP addresses, and different reset info in a safe location.

10. Detailed Information to Urgent and Holding the Reset Button

The exact time and method for urgent and holding the reset button could fluctuate relying on the digital camera mannequin. Seek the advice of the producer’s person handbook or on-line documentation for particular directions:

Digital camera Mannequin Reset Button Directions
Mannequin X Press and maintain for 10 seconds, then launch when the LED mild turns orange.
Mannequin Y Press and maintain for 15 seconds, then launch when the LED mild flashes inexperienced.
Mannequin Z Press and maintain for 20 seconds, then launch when the digital camera reboots.

The way to Reset HJT IP Digital camera to Manufacturing unit Settings

To reset your HJT IP digital camera to manufacturing unit defaults, comply with these steps:

  1. Unplug the digital camera from the ability supply.
  2. Find the reset button on the digital camera. It’s normally a small, recessed button.
  3. Press and maintain the reset button for about 10 seconds.
  4. Launch the reset button.
  5. Plug the digital camera again into the ability supply.
  6. The digital camera will now be reset to manufacturing unit defaults.

Individuals Additionally Ask about The way to Reset HJT IP Digital camera to Manufacturing unit Settings

How do I do know if my HJT IP digital camera has been reset?

After you reset your HJT IP digital camera, you have to to reconfigure it. This implies you have to to enter the digital camera’s IP tackle, username, and password.

What are the default login credentials for HJT IP cameras?

The default login credentials for HJT IP cameras are:

  • Username: admin
  • Password: 12345

Can I reset my HJT IP digital camera with out unplugging it?

No, you can’t reset your HJT IP digital camera with out unplugging it.