Embark on a seamless glucose monitoring journey with the OneTouch Extremely 2. Designed to simplify diabetes administration, this compact and user-friendly system combines accuracy and comfort. Its superior expertise empowers you to watch your glucose ranges with precision, permitting you to make knowledgeable choices and keep answerable for your well being.
To get began with the OneTouch Extremely 2, comply with these easy steps. Insert a check strip into the meter. Then, apply a small blood pattern to the strip, both out of your finger or an alternate web site. The system will mechanically depend down and show your glucose studying inside seconds. You too can retailer your leads to the meter’s reminiscence for future reference or obtain them to your appropriate system.
Moreover, the OneTouch Extremely 2 affords customizable options to cater to your particular person wants. Set customized glucose targets, monitor tendencies over time, and obtain customized alerts to remain on high of your well being. Its glossy design and intuitive interface make glucose monitoring much less daunting, empowering you to take cost of your diabetes administration with confidence.
Inserting the Check Strip
To make sure correct blood glucose readings, it is essential to correctly insert the check strip into your One Contact Extremely 2 meter. Observe these detailed steps:
1. Determine the Check Strip Window: Find the oblong opening on the highest of the meter labeled “TEST STRIP.” It has a small steel contact on the left facet.
2. Insert the Check Strip: Maintain the check strip vertically with the blue contact space dealing with up. Align the blue contact space with the steel contact within the check strip window.
3. Push In Firmly: Gently push the check strip straight into the check strip window till it clicks securely in place. Don’t bend or twist the check strip.
4. Affirmation: The meter will show a blinking blood drop image to point that it has detected the check strip. If the image doesn’t seem, take away the check strip and re-insert it.
Step | Motion |
---|---|
1 | Find the check strip window. |
2 | Insert the check strip with the blue contact space dealing with up. |
3 | Push the check strip firmly till it clicks in place. |
4 | Affirm the meter’s detection of the check strip. |
By following these steps appropriately, you make sure that your One Contact Extremely 2 meter is able to present dependable blood glucose readings.
Making use of the Blood Pattern
As soon as you have washed your fingers and gathered your provides, you are prepared to use the blood pattern to the check strip.
Step 1: Put together Your Finger
1. Select a finger in your non-dominant hand.
2. Clear the fingertip with an alcohol pad and let it dry.
3. Therapeutic massage the finger from the bottom to the tip to stimulate blood stream.
Step 2: Prick Your Finger
1. Maintain the lancing system firmly towards the facet of your fingertip.
2. Press the discharge button to prick your finger.
3. Squeeze your finger gently to type a small drop of blood.
Step 3: Apply the Blood to the Check Strip
1. Contact the sting of the check strip to the drop of blood.
2. Maintain the strip flat till the blood is absorbed (often inside just a few seconds).
3. Discard the lancing system and used check strip correctly.
Steps | Description |
---|---|
Step 1 | Put together your finger by washing it, letting it dry, and stimulating blood stream. |
Step 2 | Prick your finger with the lancing system and squeeze gently to acquire a drop of blood. |
Step 3 | Contact the check strip to the sting of the blood drop and look forward to the blood to be absorbed. |
Studying the Outcomes
After you have accomplished the blood glucose check, the OneTouch Extremely 2 meter will show your blood glucose outcome on the display. The outcome can be displayed in mg/dL (milligrams per deciliter). The meter may even retailer the end in its reminiscence so that you could monitor your blood glucose ranges over time.
Understanding the Show
The OneTouch Extremely 2 meter has a big, easy-to-read show that reveals the next info:
- Your blood glucose end in mg/dL
- The date and time of the check
- The check quantity
- The battery stage
Decoding Your Outcomes
After you have your blood glucose outcome, you will need to interpret it appropriately. The American Diabetes Affiliation (ADA) recommends the next goal blood glucose ranges for individuals with diabetes:
Time | Goal Blood Glucose Vary (mg/dL) |
---|---|
Earlier than meals | 80-130 |
2 hours after meals | 110-150 |
Bedtime | 100-140 |
In case your blood glucose result’s outdoors of those ranges, you need to discuss to your physician. They’ll make it easier to develop a plan to handle your blood glucose ranges and forestall issues.
Setting Up the Meter
1. Inserting the Batteries
Open the battery compartment on the again of the meter. Insert two 3-volt CR2032 batteries with the constructive (+) facet dealing with up. Shut the battery compartment securely.
2. Inserting the Check Strip
Maintain the meter dealing with you with the check strip port on the backside. Insert a OneTouch Extremely 2 check strip into the port till it clicks into place. The meter will activate mechanically.
3. Making use of the Blood Pattern
Wash your fingers and dry them totally. Prick the facet of your finger with the supplied lancing system. Gently squeeze your finger to launch a small drop of blood onto the check strip. The meter will draw the blood into the check strip and show the leads to just a few seconds.
4. Setting the Time and Date
After inserting the batteries and check strip, the meter will show the time and date. To regulate them, comply with these steps:
Press… | To… |
---|---|
The “Set” button |
Enter the time and date setting mode |
The up or down arrow buttons |
Regulate the hour, minute, month, day, and 12 months |
The “Set” button once more |
Affirm your settings and exit the setting mode |
Notice: If you don’t regulate the time and date, the meter will proceed to make use of the default settings.
Calibrating the Meter
Calibration is an important step in guaranteeing your One Contact Extremely 2 meter offers correct blood glucose readings. This is a step-by-step information to calibrate your meter:
- Wash your fingers totally with cleaning soap and water.
- Insert a check strip into the meter.
- Apply a small drop of management answer to the check strip.
- Anticipate the meter to learn the management answer and show a outcome.
-
- If the result’s inside the acceptable vary (confer with the desk under for acceptable ranges), press the “Settle for” button to finalize the calibration.
- If the result’s outdoors the suitable vary, an error message will seem. Repeat steps 2-4 utilizing a recent check strip till a outcome inside the acceptable vary is obtained.
Management Answer Degree | Acceptable Glucose Focus Vary |
---|---|
Low | 40-60 mg/dL (2.2-3.3 mmol/L) |
Excessive | 200-240 mg/dL (11.1-13.3 mmol/L) |
Storing the Meter and Check Strips
Storing the Meter
To make sure correct outcomes, retailer your OneTouch Extremely 2 meter in a cool, dry place. Don’t expose it to excessive temperatures or humidity. Hold it away from direct daylight, as this could injury the digital elements. When not in use, retailer the meter in its protecting case.
Storing the Check Strips
Your OneTouch Extremely 2 check strips are delicate to moisture and lightweight. Retailer them within the unique container, which ought to be saved tightly closed. Don’t retailer the check strips within the fridge or freezer, as this could have an effect on their accuracy. As soon as opened, the check strips ought to be used inside six months. It’s essential to make use of recent check strips for every blood glucose studying to stop incorrect outcomes.
Ideas for Optimum Storage:
- Hold the check strips and meter away from meals and drinks that emit sturdy odors.
- Keep away from storing the check strips in areas with excessive air air pollution or mud.
- If you have to transport the meter or check strips for an prolonged interval, retailer them in an insulated cooler with ice packs.
Discarding Used Check Strips:
Get rid of used check strips correctly. Wrap them securely in paper or a sealed plastic bag earlier than discarding them in a trash container.
Part | Storage Situations |
---|---|
Meter | Cool, dry place, away from daylight |
Check Strips | Authentic container, tightly closed, at room temperature |
Troubleshooting Error Codes
For those who encounter an error code whereas utilizing your One Contact Extremely 2 blood glucose meter, comply with these steps to resolve the problem:
1. Confirm the Check Strip
Make sure that the check strip is inserted appropriately and isn’t broken or expired.
2. Test the Blood Pattern Dimension
Just remember to have utilized sufficient blood to the check strip. If the pattern is simply too small, the meter won’t be able to precisely measure your blood sugar.
3. Clear the Meter and Check Strip Port
Dust or particles on the meter or check strip port can intrude with the studying. Clear each areas with a tender, dry material.
4. Make sure the Meter Is Calibrated
Calibrating your meter commonly is crucial for correct readings. Observe the directions supplied within the consumer handbook to calibrate your system.
5. Substitute the Batteries
Weak batteries can have an effect on the meter’s efficiency. If the error code persists, substitute the batteries with new ones.
6. Reset the Meter
Resetting the meter can typically resolve minor points. Seek advice from the consumer handbook for particular directions on reset your system.
7. Widespread Error Codes and Their Meanings
The desk under lists some frequent error codes and their corresponding meanings:
Error Code | That means |
---|---|
E-1 | Invalid check strip |
E-2 | Inadequate blood pattern |
E-3 | Meter malfunction |
E-4 | Calibration error |
E-5 | Low battery |
Understanding Check Outcomes
The One Contact Extremely 2 blood glucose meter offers correct readings, however understanding the outcomes is essential for efficient diabetes administration.
The meter shows the blood glucose stage in mg/dL (milligrams per deciliter) alongside particular symbols to point the vary of the outcome:
1. Low Blood Sugar (Hypoglycemia):
- Image: Arrow pointing down
- Vary: Beneath 70 mg/dL
- Signs could embody shakiness, sweating, starvation, and confusion.
2. Regular Blood Sugar:
- Image: No show
- Vary: 70 – 180 mg/dL
- This vary signifies good management and minimal threat of issues.
3. Excessive Blood Sugar (Hyperglycemia):
- Image: Arrow pointing up
- Vary: Above 180 mg/dL
- Signs could embody elevated thirst, frequent urination, and blurred imaginative and prescient.
4. Excessive Blood Ketones:
- Image: “KE”
- Presence of ketones, a byproduct of fats breakdown, signifies the necessity for insulin.
5. Check Error:
- Image: “ERR”
- Signifies an error throughout testing, requiring additional troubleshooting.
6. Management Answer Vary:
- Image: “LO” or “HI”
- Signifies the check strip will not be working appropriately and requires substitute.
7. Battery Indicator:
- Image: Battery icon
- Signifies the battery stage, requiring substitute when low.
8. Reminiscence Perform:
- Image: “M” or “AVG”
- Permits customers to retailer and retrieve earlier blood glucose readings, serving to with monitoring and evaluation.
- The meter can retailer as much as 500 readings, offering a complete historical past of blood glucose ranges.
- The “AVG” operate calculates the typical of the saved readings, giving an total view of latest glucose management.
9. Bluetooth Connectivity:
- Image: Bluetooth icon
- Allows wi-fi connection to appropriate units, permitting for information sharing and distant monitoring.
- Customers can join the meter to their smartphone or pc to entry further options and obtain alerts.
Further Options and Capabilities
A number of Studying Modes
The One Contact Extremely 2 affords three studying modes: commonplace, daring, and excessive distinction. The usual mode shows the readings in a transparent, easy-to-read format. The daring mode makes the numbers bigger and darker, making it simpler to learn from a distance. The excessive distinction mode inverts the colours of the show, making a black background with white numbers for improved readability in low-light situations.
Hypoglycemia Alert
The One Contact Extremely 2 can provide you with a warning in case your blood sugar stage drops under a set threshold. This helps you’re taking immediate motion to lift your blood sugar and forestall hypoglycemia, a harmful situation that happens when blood sugar ranges grow to be dangerously low.
Ketone Detection
The One Contact Extremely 2 may also detect ketones in your urine, a sign that your physique is breaking down fats for vitality. Excessive ketone ranges generally is a signal of diabetic ketoacidosis (DKA), a critical medical situation that requires speedy therapy.
PC Connectivity
The One Contact Extremely 2 will be linked to a pc utilizing a USB cable. This lets you obtain your blood sugar readings to a pc and share them together with your healthcare supplier or use software program to trace and analyze your readings.
Different Helpful Options
Further options of the One Contact Extremely 2 embody:
- Goal Vary Indicator: Exhibits you in case your blood sugar studying is inside your goal vary.
- Meal Tagging: Means that you can tag your readings with a dinner time to trace how meals impacts your blood sugar.
- Common Calculator: Calculates the typical of your readings over a specified interval.
- Stat Reminiscence: Shops as much as 500 readings for evaluate.
- Carrying Case: Protects the meter when not in use.
- Replaceable Batteries: Two CR2032 batteries energy the meter, which might last as long as 3,000 readings.
Glycemic Index Calculator
The One Contact Extremely 2 may also calculate the glycemic index (GI) of meals you eat. The GI measures how rapidly a meals raises your blood sugar ranges. This info may also help you make more healthy meals selections and handle your blood sugar extra successfully.
Characteristic | Description |
---|---|
A number of Studying Modes | Commonplace, Daring, Excessive Distinction |
Hypoglycemia Alert | Alerts you in case your blood sugar stage drops under a set threshold |
Ketone Detection | Can detect ketones in your urine, indicating fats burning |
PC Connectivity | Means that you can obtain readings to a pc for evaluation |
Goal Vary Indicator | Exhibits in case your studying is inside your goal vary |
Meal Tagging | Tag readings with dinner time to trace meals results |
Common Calculator | Calculates the typical of readings over a specified interval |
Stat Reminiscence | Shops as much as 500 readings for evaluate |
Glycemic Index Calculator | Calculates the GI of meals you eat to assist with meals selections |
Ideas for Correct Readings
To make sure correct readings together with your One Contact Extremely 2 blood glucose monitor, comply with the following pointers:
1. Wash Your Arms
Earlier than dealing with the meter, check strips, or lancing system, totally wash your fingers with cleaning soap and water to stop contamination.
2. Use Recent Check Strips
Every check strip is designed for one-time use. Don’t reuse check strips as they could give inaccurate outcomes.
3. Insert the Check Strip Accurately
Align the check strip’s contact bars with the corresponding steel contacts on the meter. The meter will beep to point a profitable connection.
4. Apply a Ample Blood Pattern
Place a drop of blood on the designated space of the check strip. Don’t apply an excessive amount of blood, as this could intrude with the studying.
5. Do Not Wipe Away Extra Blood
Don’t use a tissue or cotton ball to wipe away extra blood from the check strip. This will alter the blood pattern and have an effect on the accuracy of the studying.
6. Learn the End result Rapidly
Outcomes ought to be learn inside 60 seconds of making use of the blood pattern to the check strip. After this time, the studying could grow to be inaccurate.
7. Report Your Readings
Hold a log of your blood glucose readings to trace your progress and make knowledgeable choices concerning your well being.
8. Test the Management Answer
Repeatedly check the meter utilizing the supplied management answer to make sure it’s functioning appropriately.
9. Substitute Batteries Repeatedly
Substitute the batteries within the meter when the battery indicator seems. Low batteries can have an effect on the accuracy of readings.
10. Think about the Following Elements
Elements | Affect on Readings |
---|---|
Humidity | Could have an effect on accuracy, particularly if > 90% or < 20% |
Temperature | Readings could also be inaccurate outdoors the vary of 41-113°F |
Altitude | Excessive altitudes could require completely different calibration |
Electromagnetic Fields | Could intrude with readings, stay away from energy strains |
How To Use One Contact Extremely 2
The OneTouch Extremely 2 blood glucose meter is an easy and easy-to-use system that may make it easier to handle your diabetes. Listed here are the steps on use it:
- Wash your fingers with cleaning soap and water.
- Insert a check strip into the meter.
- Prick your finger with the lancing system.
- Apply a small drop of blood to the check strip.
- Anticipate the meter to show your blood glucose stage.
Folks Additionally Ask
How typically ought to I verify my blood sugar?
The frequency of blood sugar checks will range relying in your particular person wants and diabetes administration plan. Nonetheless, it’s usually really helpful to verify your blood sugar ranges at the least as soon as a day, and extra typically in case you are experiencing signs of excessive or low blood sugar.
What’s a traditional blood sugar stage?
A traditional blood sugar stage for adults is between 70 and 110 mg/dL earlier than meals and fewer than 140 mg/dL two hours after meals. Nonetheless, these ranges could range barely relying in your age, exercise stage, and different elements.
What ought to I do if my blood sugar is excessive or low?
In case your blood sugar is excessive, you need to drink loads of fluids and take your insulin as directed by your physician. In case your blood sugar is low, you need to eat or drink one thing sugary, resembling a chunk of fruit or a glass of juice.